Baden-Württemberg's LBO BW sets a 2.30 m minimum room height — lower than the 2.40 m most other Länder use. Here's the figure and what to confirm yourself.

- Canonical HTML: https://www.chippy.tools/building-codes/de/bw/
- Publisher: Chippy Tools
- Language: en
- Updated: 2026-09-13

[Browse all topics](https://www.chippy.tools/building-codes/topics/)[Free web tools](https://www.chippy.tools/building-codes/tools/)[Printable references](https://www.chippy.tools/building-codes/printables/)

[All countries](https://www.chippy.tools/building-codes/) [Germany](https://www.chippy.tools/building-codes/de/)

Topics

Stairs

- [German Stair Rules: DIN 18065 Rise, Going & Guard Heights](https://www.chippy.tools/building-codes/de/stairs/stair-and-guard-requirements/)

Footings

- [Does Germany Have a Fixed Foundation Depth?](https://www.chippy.tools/building-codes/de/footings/foundation-depth-and-footings/)

Room heights

- [Minimum Room Height by Bundesland: Germany Land by Land](https://www.chippy.tools/building-codes/de/room-heights-by-bundesland/)
- [Does Germany Have a National Minimum Room Height?](https://www.chippy.tools/building-codes/de/rooms/minimum-room-heights/)

Ramps

- [German Ramp Gradients: DIN 18040-2 Accessible Ramp Rules](https://www.chippy.tools/building-codes/de/ramps/ramp-gradients/)

Wet areas

- [German Wet-Room Waterproofing: Check DIN and Land Rules](https://www.chippy.tools/building-codes/de/wet-areas/waterproofing-requirements/)

By Land

- [Brandenburg](https://www.chippy.tools/building-codes/de/bb/)
- [Berlin](https://www.chippy.tools/building-codes/de/be/)
- [Baden-Württemberg](https://www.chippy.tools/building-codes/de/bw/)
- [Bayern](https://www.chippy.tools/building-codes/de/by/)
- [Bremen](https://www.chippy.tools/building-codes/de/hb/)
- [Hessen](https://www.chippy.tools/building-codes/de/he/)
- [Hamburg](https://www.chippy.tools/building-codes/de/hh/)
- [Mecklenburg-Vorpommern](https://www.chippy.tools/building-codes/de/mv/)
- [Niedersachsen](https://www.chippy.tools/building-codes/de/ni/)
- [Nordrhein-Westfalen](https://www.chippy.tools/building-codes/de/nw/)
- [Rheinland-Pfalz](https://www.chippy.tools/building-codes/de/rp/)
- [Schleswig-Holstein](https://www.chippy.tools/building-codes/de/sh/)
- [Saarland](https://www.chippy.tools/building-codes/de/sl/)
- [Sachsen](https://www.chippy.tools/building-codes/de/sn/)
- [Sachsen-Anhalt](https://www.chippy.tools/building-codes/de/st/)
- [Thüringen](https://www.chippy.tools/building-codes/de/th/)

Calculation guides

- [Concrete Calculations: The Complete On-Site Guide](https://www.chippy.tools/building-codes/concrete/concrete-calculations-guide/)
- [How to Calculate Concrete Volume for a Slab](https://www.chippy.tools/building-codes/concrete/concrete-volume-slab/)
- [How Many Bags of Concrete Per m³? (20kg, 25kg, 40kg)](https://www.chippy.tools/building-codes/concrete/bags-of-concrete-per-m3/)
- [Concrete for Post Holes: Volume Per Hole & Bags Needed](https://www.chippy.tools/building-codes/concrete/concrete-post-holes/)
- [Concrete Mix Ratios Explained: 1:2:3, 1:2:4 & Water-Cement Ratio](https://www.chippy.tools/building-codes/concrete/concrete-mix-ratios/)
- [Roof Pitch to Angle: Convert Rise/Run to Degrees & Grade](https://www.chippy.tools/building-codes/concrete/roof-pitch-to-angle/)
- [Rafter Length Calculation: Run, Rise & Overhang](https://www.chippy.tools/building-codes/concrete/rafter-length/)
- [Stair Rise & Run Setout: Riser, Going & the 2R+G Formula](https://www.chippy.tools/building-codes/concrete/stair-rise-and-run-setout/)
- [How to Convert a Fall or Gradient: Ratio, Percentage & Degrees](https://www.chippy.tools/building-codes/concrete/fall-and-gradient-conversion/)
- [Stud & Joist Spacing Takeoff: How Many at 400, 450 & 600 mm Centres](https://www.chippy.tools/building-codes/concrete/stud-and-joist-spacing-takeoff/)
- [Gravel & Base Volume: Compacted Depth vs Loose-Fill Order Quantity](https://www.chippy.tools/building-codes/concrete/gravel-and-base-volume/)

In this section

[Browse all topics](https://www.chippy.tools/building-codes/topics/)[Free web tools](https://www.chippy.tools/building-codes/tools/)[Printable references](https://www.chippy.tools/building-codes/printables/)

[All countries](https://www.chippy.tools/building-codes/) [Germany](https://www.chippy.tools/building-codes/de/)

Topics

Stairs

- [German Stair Rules: DIN 18065 Rise, Going & Guard Heights](https://www.chippy.tools/building-codes/de/stairs/stair-and-guard-requirements/)

Footings

- [Does Germany Have a Fixed Foundation Depth?](https://www.chippy.tools/building-codes/de/footings/foundation-depth-and-footings/)

Room heights

- [Minimum Room Height by Bundesland: Germany Land by Land](https://www.chippy.tools/building-codes/de/room-heights-by-bundesland/)
- [Does Germany Have a National Minimum Room Height?](https://www.chippy.tools/building-codes/de/rooms/minimum-room-heights/)

Ramps

- [German Ramp Gradients: DIN 18040-2 Accessible Ramp Rules](https://www.chippy.tools/building-codes/de/ramps/ramp-gradients/)

Wet areas

- [German Wet-Room Waterproofing: Check DIN and Land Rules](https://www.chippy.tools/building-codes/de/wet-areas/waterproofing-requirements/)

By Land

- [Brandenburg](https://www.chippy.tools/building-codes/de/bb/)
- [Berlin](https://www.chippy.tools/building-codes/de/be/)
- [Baden-Württemberg](https://www.chippy.tools/building-codes/de/bw/)
- [Bayern](https://www.chippy.tools/building-codes/de/by/)
- [Bremen](https://www.chippy.tools/building-codes/de/hb/)
- [Hessen](https://www.chippy.tools/building-codes/de/he/)
- [Hamburg](https://www.chippy.tools/building-codes/de/hh/)
- [Mecklenburg-Vorpommern](https://www.chippy.tools/building-codes/de/mv/)
- [Niedersachsen](https://www.chippy.tools/building-codes/de/ni/)
- [Nordrhein-Westfalen](https://www.chippy.tools/building-codes/de/nw/)
- [Rheinland-Pfalz](https://www.chippy.tools/building-codes/de/rp/)
- [Schleswig-Holstein](https://www.chippy.tools/building-codes/de/sh/)
- [Saarland](https://www.chippy.tools/building-codes/de/sl/)
- [Sachsen](https://www.chippy.tools/building-codes/de/sn/)
- [Sachsen-Anhalt](https://www.chippy.tools/building-codes/de/st/)
- [Thüringen](https://www.chippy.tools/building-codes/de/th/)

Calculation guides

- [Concrete Calculations: The Complete On-Site Guide](https://www.chippy.tools/building-codes/concrete/concrete-calculations-guide/)
- [How to Calculate Concrete Volume for a Slab](https://www.chippy.tools/building-codes/concrete/concrete-volume-slab/)
- [How Many Bags of Concrete Per m³? (20kg, 25kg, 40kg)](https://www.chippy.tools/building-codes/concrete/bags-of-concrete-per-m3/)
- [Concrete for Post Holes: Volume Per Hole & Bags Needed](https://www.chippy.tools/building-codes/concrete/concrete-post-holes/)
- [Concrete Mix Ratios Explained: 1:2:3, 1:2:4 & Water-Cement Ratio](https://www.chippy.tools/building-codes/concrete/concrete-mix-ratios/)
- [Roof Pitch to Angle: Convert Rise/Run to Degrees & Grade](https://www.chippy.tools/building-codes/concrete/roof-pitch-to-angle/)
- [Rafter Length Calculation: Run, Rise & Overhang](https://www.chippy.tools/building-codes/concrete/rafter-length/)
- [Stair Rise & Run Setout: Riser, Going & the 2R+G Formula](https://www.chippy.tools/building-codes/concrete/stair-rise-and-run-setout/)
- [How to Convert a Fall or Gradient: Ratio, Percentage & Degrees](https://www.chippy.tools/building-codes/concrete/fall-and-gradient-conversion/)
- [Stud & Joist Spacing Takeoff: How Many at 400, 450 & 600 mm Centres](https://www.chippy.tools/building-codes/concrete/stud-and-joist-spacing-takeoff/)
- [Gravel & Base Volume: Compacted Depth vs Loose-Fill Order Quantity](https://www.chippy.tools/building-codes/concrete/gravel-and-base-volume/)

[Building Codes](https://www.chippy.tools/building-codes/) [Germany](https://www.chippy.tools/building-codes/de/) Baden-Württemberg

# Building Code Requirements in Baden-Württemberg

Baden-Württemberg's LBO BW sets a 2.30 m minimum room height — lower than the 2.40 m most other Länder use. Here's the figure and what to confirm yourself.

Baden-Württemberg’s building law is the **Landesbauordnung Baden-Württemberg (LBO BW)**, currently in force. As with every Land, it’s the LBO — not the national Musterbauordnung model — that actually binds you here.

**Minimum room height (lichte Raumhöhe): 2.30 m**, set directly in **§34(1) LBO BW** — lower than the 2.40 m most other Länder use. In a roof space, that reduces further to **2.20 m** over at least half the room’s floor area, with any part of the room under a lower clear height simply not counting toward that half.

Baden-Württemberg is also one of the few Länder where the boundary-setback (Abstandsflächen) rule is confirmed: the general depth factor is **0.4 × wall height**, with a minimum absolute depth of around **2.5 m** — per **§5(7) LBO BW**. Reduced rates apply in some zoning categories — confirm those against **§5(7) LBO BW** directly. Your LBO also sets guard/parapet (Umwehrung) heights and permit-free (verfahrensfrei) thresholds for garages and carports — these weren’t independently confirmed for Baden-Württemberg, so check them directly in the [LBO BW text on landesrecht-bw.de](https://www.landesrecht-bw.de/) before you build to a number.

## Related

- [**German building rules hub**](https://www.chippy.tools/building-codes/de/) — how the national DIN layer and the 16 Länder’s own building law fit together.
- [**Minimum room heights across Germany**](https://www.chippy.tools/building-codes/de/rooms/minimum-room-heights/) — why there’s no single national figure.
- [**German stair & guard rules**](https://www.chippy.tools/building-codes/de/stairs/stair-and-guard-requirements/) — the DIN 18065 numbers plus the Land-by-Land guard-height picture.

## Adoption status

Adopted

Current code in force

Landesbauordnung Baden-Württemberg (LBO BW)

Next edition

Not announced

Adoption / transition

LBO BW sets a 2.30 m minimum room height (§34(1)) — lower than the 2.40 m most other Länder use.

[Official source →](https://www.landesrecht-bw.de/)

Last verified 2026-07-29

## State variations

- DE LBO
  
  Baden-Württemberg's LBO BW sets minimum room height at 2.30 m (§34(1)), not the 2.40 m most Länder use.
  
  [Source →](https://www.landesrecht-bw.de/) Related: [Does Germany Have a National Minimum Room Height?](https://www.chippy.tools/building-codes/de/rooms/minimum-room-heights/) Verified 2026-07-29