<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Spanish Building Regulations: One National Code on Chippy Tools</title><link>https://www.chippy.tools/building-codes/es/</link><description>Recent content in Spanish Building Regulations: One National Code on Chippy Tools</description><generator>Hugo</generator><language>en</language><lastBuildDate>Tue, 04 Aug 2026 22:01:18 +1000</lastBuildDate><atom:link href="https://www.chippy.tools/building-codes/es/index.xml" rel="self" type="application/rss+xml"/><item><title>Spanish Minimum Roof Pitch (CTE DB-HS1): By Material</title><link>https://www.chippy.tools/building-codes/es/roofing/minimum-roof-pitch/</link><pubDate>Tue, 04 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/es/roofing/minimum-roof-pitch/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;&lt;strong&gt;Roof pitch&lt;/strong&gt; — pendiente, in the CTE — is how steep a roof plane is. Lay a
material flatter than it can handle and rain works its way back under the
laps instead of running off. Spain&amp;rsquo;s national building code, the &lt;strong&gt;Código
Técnico de la Edificación (CTE)&lt;/strong&gt;, fixes this material by material in
&lt;strong&gt;Documento Básico HS, Sección HS1 &amp;ldquo;Protección frente a la humedad&amp;rdquo;&lt;/strong&gt;,
§2.4.3.1, &lt;strong&gt;Tabla 2.10&lt;/strong&gt;.&lt;/p&gt;
&lt;p&gt;Unlike a single national minimum, DB-HS1 gives a &lt;strong&gt;different pendiente for
every roofing material and profile&lt;/strong&gt; — because a deep tile profile sheds
water differently to a flat sheet:&lt;/p&gt;</description></item><item><title>Spanish Wet-Room Waterproofing: What CTE DB-HS1 Doesn't Cover</title><link>https://www.chippy.tools/building-codes/es/wet-areas/waterproofing-requirements/</link><pubDate>Tue, 04 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/es/wet-areas/waterproofing-requirements/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;Here&amp;rsquo;s the honest answer: &lt;strong&gt;CTE DB-HS1 sets no shower or wet-room membrane
requirement.&lt;/strong&gt; Unlike Approved Document C in the UK or TGD C in Ireland,
DB-HS1 is freely published and genuinely official — but its scope, like
theirs, is the &lt;strong&gt;building envelope&lt;/strong&gt;, not internal wet-room tanking.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Documento Básico HS1&lt;/strong&gt;, &amp;ldquo;Protección frente a la humedad&amp;rdquo; (protection
against damp), part of the CTE&amp;rsquo;s Salubridad (HS) basic-document set, deals
with damp coming from the &lt;strong&gt;ground&lt;/strong&gt; (through floors and foundations), from
&lt;strong&gt;façades&lt;/strong&gt; (driving rain, wall construction), and from &lt;strong&gt;roofs&lt;/strong&gt;. A direct
read of DB-HS1 confirms it does not itemise shower recess, bath surround or
wet-room floor waterproofing detail — there&amp;rsquo;s no membrane-extent table or
wall-height figure for a bathroom anywhere in it.&lt;/p&gt;</description></item><item><title>Does Spain Have a National Minimum Room Height?</title><link>https://www.chippy.tools/building-codes/es/rooms/minimum-ceiling-heights/</link><pubDate>Tue, 04 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/es/rooms/minimum-ceiling-heights/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;Here&amp;rsquo;s the short answer: &lt;strong&gt;the CTE sets no national minimum ceiling height&lt;/strong&gt;
for a dwelling. There&amp;rsquo;s no single figure in the national building code you&amp;rsquo;re
required to hit — and unlike Ireland&amp;rsquo;s TGDs, which simply leave the question
open, Spain hands it to a &lt;strong&gt;different legal instrument entirely&lt;/strong&gt;.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;No fixed ceiling height in the CTE.&lt;/strong&gt; A full search of DB-SUA, DB-SE-C and
DB-HS turns up no habitable-room height minimum anywhere in the national
code. The only height figure the CTE carries at all is DB-SUA 2&amp;rsquo;s headroom
rule — 2.10 m in restricted-use circulation zones, 2.20 m elsewhere — and
the Ministry&amp;rsquo;s own comment on that clause confirms it applies to
&lt;strong&gt;circulation zones&lt;/strong&gt;, hallways and landings, not to a living or sleeping
room. Don&amp;rsquo;t read a headroom figure onto a bedroom ceiling.&lt;/p&gt;</description></item><item><title>Spanish Foundations: No Fixed Depth, a Table-Driven Width (CTE DB-SE-C)</title><link>https://www.chippy.tools/building-codes/es/footings/footing-sizes-and-depth/</link><pubDate>Tue, 04 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/es/footings/footing-sizes-and-depth/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;A standard shallow foundation in Spain is built to &lt;strong&gt;DB-SE-C&lt;/strong&gt;, the
Documento Básico &amp;ldquo;Seguridad Estructural: Cimientos&amp;rdquo; — the CTE&amp;rsquo;s structural
foundations document. Before you reach for a tape, there&amp;rsquo;s a catch: &lt;strong&gt;DB-SE-C
does not set a fixed foundation depth.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;No frost-line rule, no fixed depth — for an ordinary footing.&lt;/strong&gt; Unlike some
countries, Spain has no frost-depth number to dig below. DB-SE-C §4.2–§4.3
sets the depth of a shallow foundation by the project&amp;rsquo;s &lt;strong&gt;geotechnical study&lt;/strong&gt;
(informe geotécnico) and a bearing-capacity/settlement calculation, not by a
number printed in the document. Whatever your site investigation calls for is
the depth you dig to.&lt;/p&gt;</description></item><item><title>Spanish Ramp Gradients: General Ramp vs Accessible Itinerary (CTE DB-SUA)</title><link>https://www.chippy.tools/building-codes/es/ramps/ramp-gradients/</link><pubDate>Tue, 04 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/es/ramps/ramp-gradients/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;Spain doesn&amp;rsquo;t set one ramp number — it sets &lt;strong&gt;two&lt;/strong&gt;, and which one applies to
your job depends on where the ramp is and what it connects. Both live in the
same Documento Básico, &lt;strong&gt;DB-SUA&lt;/strong&gt;, but in different sections.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;DB-SUA 1 — the general ramp.&lt;/strong&gt; For a ramp that isn&amp;rsquo;t part of an accessible
itinerary — an internal change of level, a minor structural ramp, most of
what happens inside or around an ordinary house — the slope is capped at
&lt;strong&gt;12%&lt;/strong&gt; (§4.3.1.1). Any path sloped over 4% counts as a &amp;ldquo;rampa&amp;rdquo; under the
CTE&amp;rsquo;s own definition. A general ramp also needs:&lt;/p&gt;</description></item><item><title>Spanish Stair &amp; Barrier Rules: Riser, Going, Handrails, Guarding</title><link>https://www.chippy.tools/building-codes/es/stairs/stair-and-barrier-requirements/</link><pubDate>Tue, 04 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/es/stairs/stair-and-barrier-requirements/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;A Spanish dwelling&amp;rsquo;s internal stair is built to &lt;strong&gt;DB-SUA 1&lt;/strong&gt;, the Documento
Básico for &amp;ldquo;Seguridad de Utilización y Accesibilidad&amp;rdquo; — safety in use and
accessibility. Before you read off a single number, though, get the
classification right: the CTE&amp;rsquo;s own glossary (Anejo A) classes the interior
of a single-family or attached dwelling as &lt;strong&gt;&amp;ldquo;uso restringido&amp;rdquo;&lt;/strong&gt; — restricted
use. That matters, because DB-SUA 1 also sets out a separate, stricter &amp;ldquo;uso
general&amp;rdquo; class for shared and public stairs, with different (and in one case,
extra) rules. This page covers &lt;strong&gt;uso restringido&lt;/strong&gt; — a house&amp;rsquo;s own stair.&lt;/p&gt;</description></item></channel></rss>