<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Indonesian Building Rules: One National Rule Book on Chippy Tools</title><link>https://www.chippy.tools/building-codes/id/</link><description>Recent content in Indonesian Building Rules: One National Rule Book on Chippy Tools</description><generator>Hugo</generator><language>en</language><lastBuildDate>Thu, 06 Aug 2026 08:57:28 +1000</lastBuildDate><atom:link href="https://www.chippy.tools/building-codes/id/index.xml" rel="self" type="application/rss+xml"/><item><title>Does Indonesia Have a Wet-Area Waterproofing Standard?</title><link>https://www.chippy.tools/building-codes/id/wet-areas/waterproofing-requirements/</link><pubDate>Thu, 06 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/id/wet-areas/waterproofing-requirements/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;No. There is no confirmed national rule for wet room membranes in
Indonesia. &lt;strong&gt;SNI 8153&lt;/strong&gt;, the national plumbing standard, covers pipes and
drains, not membranes. &lt;strong&gt;Permen PU 29/2006&lt;/strong&gt;, the general building rule,
is silent too. On site, your guide is the membrane maker&amp;rsquo;s data sheet,
not a code.&lt;/p&gt;
&lt;p&gt;This is the thinnest page in this cluster. It stays that way on purpose.
We will not invent a clause to fill the gap.&lt;/p&gt;</description></item><item><title>Does Indonesia Have a Minimum Ceiling Height?</title><link>https://www.chippy.tools/building-codes/id/rooms/minimum-ceiling-heights/</link><pubDate>Thu, 06 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/id/rooms/minimum-ceiling-heights/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;Indonesia sets &lt;strong&gt;no fixed national minimum ceiling height&lt;/strong&gt; for a house.
&lt;strong&gt;Permen PU No. 29/PRT/M/2006&lt;/strong&gt;, Bab III.2, says room height must not be less
than the set minimum. But it never states that minimum. It points to local
bylaws instead. The &lt;strong&gt;2.4–2.8 m&lt;/strong&gt; figure you often hear is not a confirmed
national rule.&lt;/p&gt;
&lt;p&gt;So who sets the number? Your local government does. Many provinces and cities
restate a ceiling height in their own &lt;em&gt;Perda Bangunan Gedung&lt;/em&gt;. Check with your
local permit office (&lt;em&gt;Dinas PUPR&lt;/em&gt;) for the figure that applies where you
build. Do not design to 2.4–2.8 m and assume it is law. It may match your
local Perda. It may not.&lt;/p&gt;</description></item><item><title>Indonesian Foundations: No Frost Rule, Design-Driven Depth</title><link>https://www.chippy.tools/building-codes/id/footings/footing-depth-and-concrete/</link><pubDate>Thu, 06 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/id/footings/footing-depth-and-concrete/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;There is &lt;strong&gt;no fixed footing depth&lt;/strong&gt; in Indonesia, and no frost line. The
rule is &lt;strong&gt;Permen PU No. 29/PRT/M/2006&lt;/strong&gt;, Bab III.3.1.d.i. It sets depth by
your ground instead. The footing base must sit on soil that can carry the
load. Your site&amp;rsquo;s soil check sets the depth you dig to.&lt;/p&gt;
&lt;p&gt;Why no frost rule? Indonesia is tropical all year, so the ground never
freezes. Cold countries make you dig below a frost line. There is no such
line here at all.&lt;/p&gt;</description></item><item><title>Indonesian Ramp Gradients: Indoor, Outdoor &amp; Landings</title><link>https://www.chippy.tools/building-codes/id/ramps/ramp-gradients-and-landings/</link><pubDate>Thu, 06 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/id/ramps/ramp-gradients-and-landings/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;A ramp inside a building is capped at &lt;strong&gt;6°&lt;/strong&gt;, a slope of 1:10. A ramp outside
is capped at &lt;strong&gt;5°&lt;/strong&gt;, or 1:12. Both limits sit in
&lt;strong&gt;Permen PUPR No. 14/PRT/M/2017&lt;/strong&gt; (&lt;em&gt;Persyaratan Kemudahan Bangunan Gedung&lt;/em&gt;),
Lampiran II, its section on &amp;ldquo;Ram&amp;rdquo;, point 1.&lt;/p&gt;
&lt;p&gt;This is the one national ramp rule. There is no separate general ramp rule
with different numbers beside it. The stair figures come from the same
document.&lt;/p&gt;</description></item><item><title>Indonesian Stair Rules: Rise, Going, Handrail Heights</title><link>https://www.chippy.tools/building-codes/id/stairs/stair-and-handrail-requirements/</link><pubDate>Thu, 06 Aug 2026 00:00:00 +0000</pubDate><guid>https://www.chippy.tools/building-codes/id/stairs/stair-and-handrail-requirements/</guid><description>&lt;h2 id="the-requirement"&gt;The requirement&lt;/h2&gt;
&lt;p&gt;Each rise must be between &lt;strong&gt;150 mm and 180 mm&lt;/strong&gt;. Each going must be at
least &lt;strong&gt;300 mm&lt;/strong&gt; deep. The handrail sits &lt;strong&gt;650–800 mm&lt;/strong&gt; above the stair.
The pitch can be no steeper than &lt;strong&gt;35°&lt;/strong&gt;. The numbers come from
&lt;strong&gt;Permen PUPR No. 14/PRT/M/2017&lt;/strong&gt;, Lampiran II.&lt;/p&gt;
&lt;p&gt;A stair has to fit the space. It also has to stay easy to climb. That is