The requirement
The IRC gives your house ramp a slope limit, and it depends on which ramp you’re building.
There are two lines to know:
| The ramp | Steepest slope allowed |
|---|---|
| The ramp serving the required exit door | 1:12 (8.3%) |
| Any other ramp at the house | 1:8 (12.5%) |
So the ramp at your front exit door is the strict one: 1 unit up for every 12 along. Every other ramp on the job can be steeper, up to 1 unit up for every 8 along.
Landings
The flat spot at each end of the ramp is the landing. You need a landing that is at least 3 ft by 3 ft (914 mm by 914 mm):
- at the top and bottom of each ramp,
- wherever a door opens onto the ramp, and
- wherever the ramp changes direction.
The landing width across the ramp is at least 36 in.
Handrails
A handrail is only needed once the ramp gets steep:
- Steeper than 1:12 — a handrail is required on at least one side.
- 1:12 or flatter — no handrail is required by the IRC.
When you do need one, the top of the handrail sits 34 to 38 in (864 to 965 mm) above the ramp. For the handrail’s grip size (how thick it is to hold), the IRC sends you to the stair-handrail rule — check R311.7.8.5.
Is there a maximum rise before a landing?
No — not for a house. This surprises people, so it’s worth saying plainly. The residential IRC sets no limit on how far a single ramp run can climb before a landing. You add landings at the top, bottom, at doors, and at direction changes — that’s it. A long straight run of any rise is allowed, as long as the slope and handrail rules above are met.
(Commercial ramps under the IBC and ADA are different — they cap a single run at 30 in of rise. That is not the residential IRC rule.)
Work it out on site
You’re building the ramp to the required exit door. The door sits 24 in above the ground. How long does the ramp need to be at 1:12?
- Pick the slope. An exit-door ramp can be 1:12 at the steepest. 1:12 means 1 unit up for every 12 units along.
- Do the math. 24 in up × 12 = 288 in, which is 24 ft of ramp run. (That 24 ft is just the math of this example, not a code number.)
- Landings. A 3 ft by 3 ft landing goes at the top and the bottom. There’s no code limit on the run length between them for a house, so one straight run is fine here.
- Handrail? At exactly 1:12 the ramp is not steeper than 1:12, so the IRC doesn’t require a handrail. Build steeper and it would.
So: about 24 ft of ramp at 1:12, with a 3 ft by 3 ft landing at each end. The slope calculator does this rise-over-run math for you.
Do it in 5 seconds
Related
- Part of the US building codes for the trades — the hub, with the state-by-state adoption picture.
- Building the stairs that ramp might replace? See the sibling stair and rail articles in the US building codes hub.
Sources
- 2021 IRC, Section R311.8 — Ramps (R311.8.1 Maximum slope, R311.8.2 Landings required, R311.8.3 Handrails required) — the 1:12 egress-ramp slope, the 1:8 slope for other ramps, the 3 ft × 3 ft landings, and the handrail trigger and 34–38 in height. Confirm at codes.iccsafe.org (also republished at up.codes/s/slope-of-ramps).
- Handrail grip size — R311.8.3.2 defers to the stair-handrail grip rule at R311.7.8.5; check that clause rather than a number here.
- Adoption caveat: The IRC is a model code with no legal force on its own. It applies only where a state or local jurisdiction adopts it, and adoption is often amended and edition-lagged — jurisdictions run editions from 2015 through 2024, and some amend the ramp slope locally. Always confirm the exact edition and any local amendments for your jurisdiction before you build.
Related building rules
More United States rules